Uncategorized

“Inovance Inverter” Installation Instructions

Is it difficult to install the Inovance inverter yourself?

Depending on your technical level, installing the Inovance inverter may require some basic technical knowledge and skills. However, Inovance provides instructions and support documents to help users install and operate the inverter easily. If you are experienced in the field or have reliable technical knowledge, installing an Inovance inverter may not be too difficult.

The importance of properly installing Inovance inverters.

+ Correct installation of Inovance inverter is very important because it directly affects the performance and reliability of the control system. Here are some reasons why correct installation is necessary:

High performance: Proper installation helps optimize the performance of the Inovance inverter. This helps save energy and reduce system operating costs.
Device protection: Incorrect settings can cause overload, overvoltage, overcurrent or unwanted fluctuations. This can cause damage and rapid wear of components of the Inovance inverter and the electrical system.
Safety: Incorrect installation can create an unsafe work environment, endangering surrounding employees and equipment. This can lead to accidents and serious losses.
Stability and reliability: Proper installation helps ensure the stability and reliability of the Inovance inverter. It helps avoid overloads, power strokes, or electronic failures, thereby extending the life and performance of the system.

+ For the above reasons, properly installing the Inovance inverter is very important to ensure efficient, safe and stable operation of the control system.

Instructions on how to install basic Inovance inverter yourself.
1. Reset the Inovance inverter

+ To reset the Inovance inverter to default or factory settings (Factory Reset or Default Settings), you can follow these steps:

  • Turn off the inverter: Make sure that the Inovance inverter is completely turned off. Disconnect power and make sure there is no active power to the inverter.
  • Identify the “Reset” key: Find the “Reset” key on the control panel of the Inovance inverter. This key is often marked or has a special symbol.
  • Press and hold the “Reset” key: Press and hold the “Reset” key for about 5-10 seconds. Make sure to hold the key for the required time.
  • Restore default settings: After pressing the “Reset” button, wait a short time for the Inovance inverter to perform the reset process. The inverter will then be reset to the default or factory settings.
  • Check settings: Turn on the inverter and check whether it has been reset to default or factory settings successfully. Review settings such as output frequency, PID parameters and other mode settings to ensure that they have been reset.
2. V/F mode (Voltage/Frequency).

+ Example: Set the Inovance drive to operate in V/F mode with an output frequency of 50 Hz and corresponding output voltage.

  • Step 1: Press MODE/ENTER key to enter parameter setting mode.
  • Step 2: Use the MENU key to access the inverter’s general settings menu.
  • Step 3: Use the INCREASE (+) and DECREASE (-) keys to move through the menu items and find “V/F Control”.
  • Step 4: Press MODE/ENTER key to enter V/F Control setting mode.
  • Step 5: Use the INCREASE (+) and DECREASE (-) keys to adjust the following parameters:
  • For example: Output Frequency: Set the desired output frequency, for example 50 Hz.
  • For example: Output Voltage: Adjust the output voltage corresponding to the output frequency, according to the V/F ratio.
  • Step 6: After adjusting the parameters, press the MODE/ENTER key to confirm the settings.
  • Step 7: Press the MENU key to exit the general settings menu.
  • Step 8: Press the RUN/STOP key to start the inverter and start operating in V/F mode.

In this example, the Inovance drive is set to run in V/F mode, where the output frequency is set to 50 Hz and the output voltage is adjusted relative to the output frequency in proportion to V /F. This ensures that the motor is supplied with the right voltage and frequency to operate efficiently.

About the author

admin

Leave a Comment